top of page
LiveBurnTexasHero.png

Live Burn Demonstrations
— Texas —

Structure Fire Demonstration

tworoomvented

Two Room Fire with Vent

Nozzle Type Equipped

​BLADE™ 160GPM @ 50PSI


Fire Behavior

Flashover Bedroom 4

Flashover Bedroom 3

Hallway fully involved with fire.


Venting Conditions

Bedroom 4 (Left) vented

Bedroom 3 (Right) non-vented


Total Water Applied

110 Gallons for total suppression


Vent Plan

Open lower panes of Bedroom 4 windows. Allow top portion to self-vent

​

Ignition Plan

​Bedroom 3 lit slightly before Bedroom 4

Floorplan

two_room_vent.png

Structure Fire Demonstration

oneroomvented

One Room Fire with Vent

Nozzle Type Equipped

​BLADE™ 160GPM @ 50PSI


Fire Behavior

Flashover in Bedroom 2
Rollover in the hallway.
Hoseline called early due to threat to power lines near the vent windows.


Venting Conditions

Bedroom 2 vented


Total Water Applied

95 Gallons for total suppression.


Vent Plan

The windows on the Bravo side of the building will be open.

Floorplan

one_room_vent.png

Structure Fire Demonstration

oneroomunvented

One Room Fire Unvented

Nozzle Type Equipped

​BLADE™ 160GPM @ 50PSI


Fire Behavior
Flashover Bedroom 1

Rollover into the living room space


Venting Conditions
Bedroom 1  unvented


Total Water Applied
60 Gallons for total suppression


Vent Plan
The room will remain unvented until knockdown is achieved.

Floorplan

one_room_unvented.png

Structure Fire Demonstration

tworoomtransitionalattack

Two Room Fire Transitional Attack

Nozzle Type Equipped

BLADE™ 160GPM @ 50PSI 

The BLADE™ pattern is adjusted to be narrow and horizontal


Fire Behavior

Flashover in the dining room & kitchen.
Rollover into the living room almost to the front door.


Venting Conditions

Dining room vented

Kitchen vented


Total Water Applied

115 Gallons for total suppression


Vent Plan

One window into the dining room will be taken; the other will be boarded over

​

Attack Plan

10-15 seconds of water. Exterior attack, then move in for final extinguishment. The line will start shallow and then move to an elevated angle of attack

Floorplan

two_room_transitional.png

Structure Fire Demonstration

largeareafire

Large Area Fire

Nozzle Type Equipped

BLADE™ 160GPM @ 50PSI 

The BLADE™ is horizontal


Fire Behavior

Flashover in the Garage and
Living Room
Heavy fire in the Dining Room


Conditions

Larger room with approximately 560 square feet flashed over.

15' wide x 35' deep


Total Water Applied

105 Gallons for total suppression


Vent Plan

Garage and living room are combined into one large room.

The front door is open.
The door from Bedroom 3 is open
​

Floorplan

large_area.png
bottom of page